Version: Pandora FMS 800 LTS
Release date: July 9, 2026
EndPoints are installed and are running on the operating systems from which they collect information, performing a check for each module.
The EndPoint’s own directives serve to collect certain data directly from the operating system (such as CPU usage, memory, events, etc.), executing operating system-specific commands following predefined scripts instructions.
The Pandora FMS Dataserver processes and stores in the database all the information generated and sent in XML files by the EndPoints.
Bug fixes
| FIX LTS# | GitLab# | Description |
|---|---|---|
|
N/A |
18991, 19086 |
Fixes have been made to the detection of deleted files and/or directories, as well as to the correct display of the time and date for those monitored items that have been modified. |
|
24355 |
19966
|
The detection of storage space running out on the system where the EndPoint is installed has been corrected, and a warning added. |
|
N/A |
20394 |
Added a routine to handle zero-value exceptions for the “module_interval” command. Other commands have also been reviewed for negative or non-numeric values; in these cases, the exception is to discard the corresponding modules and log the relevant warning message in the execution logs. |
|
N/A |
20457 |
The EndPoint executable binary update process has been corrected to properly stop and restart the service, allowing components and dependencies to be replaced. |
Improvements and small changes
| FIX LTS# | GitLab# | Description |
|---|---|---|
|
N/A |
15744
|
It has been confirmed that the SIEM log modules are only configured to be activated if necessary; in other words, they are disabled by default. |
|
20804, 22369, 23879, 24051 |
16641 |
New supported operating system: RHEL 10. |
|
23879 |
19151, 15278, 15742, 16716, 17199, 18731
|
Exception handling routines have been added for the detection and management of Systemd across the various Linux distributions on which the EndPoint PFMS is installed. The process for updating the configuration file when reinstalling the EndPoint, should this be necessary, has been reviewed. Software dependencies for EL8, EL9 and Ubuntu have been adjusted. The text strings providing information on version numbers have been updated and/or corrected. |
|
N/A |
20240 |
Optimisation of the compilation process, considering the new base code written in Go. |
|
N/A |
20446 |
For EndPoints entering or configured in standby mode, the data check process has been improved to prevent unnecessary workload on the monitored remote computer. |
Changes and known limitations
| FIX LTS# | GitLab# | Description |
|---|---|---|
|
N/A |
19483 |
The warning messages were removed during the FIM installation detection process (version 7.0.20260127). |
|
N/A |
19761
|
We have implemented code in the Go language, which is an environment that performs more checks prior to each compilation, thereby extending the exception-handling routines. |
|
N/A |
19772
|
The modules relating to Inventory and Security, features that were already disabled by default, were removed and/or optimised from the default configuration file at the time of EndPoint installation. These modules are now added when these features are enabled. |
|
N/A |
20451 |
Added an explicit parameter to display the EndPoint version. |