1 Star2 Stars3 Stars4 Stars5 Stars (No Ratings Yet)
Loading...
:

We can configure the following modules as remote network modules to monitor HP DL380 systems through their correspondent OIDS. For this monitoring we should know the Ip of the system that we want to monitro and the snmp community to which it belongs.

Module data

Module: Status of the ventilator 1
OID: .1.3.6.1.4.1.232.6.2.6.7.1.9.0.1
Module kind: Remote SNMP network agent, boolean data

Module: Status of the ventilator2
OID: .1.3.6.1.4.1.232.6.2.6.7.1.9.0.2
Module kind: Remote SNMP network agent, boolean data

Module: Status of the ventilator 3
OID: .1.3.6.1.4.1.232.6.2.6.7.1.9.0.3
Module kind: Remote SNMP network agent, boolean data

Module: Status of the ventilator 4
OID: .1.3.6.1.4.1.232.6.2.6.7.1.9.0.4
Module kind: Remote SNMP network agent, boolean data

Module: Status of the ventilator 5
OID: .1.3.6.1.4.1.232.6.2.6.7.1.9.0.5
Module kind: Remote SNMP network agent, boolean data

Module: Status power source 1
OID: .1.3.6.1.4.1.232.6.2.9.3.1.4.0.1
Module kind: Remote SNMP network agent, boolean data

Module: Status power source 2
OID: .1.3.6.1.4.1.232.6.2.9.3.1.4.0.2
Module kind: Remote SNMP network agent, boolean data

Module: Status Chasis temperature
OID: .1.3.6.1.4.1.232.6.2.6.3.0
Module kind: Remote SNMP network agent, boolean data

(Visited 597 times, 1 visits today)

For correct visualization of the Pandora FMS library extension, you must have installed version NG 760 or superior

X