We can configure the following modules as remote network modules to monitor F5 systems through their correspondent OID.For this monitoring we should know the Ip of the system that we want to monitor and the snmp community to which it belongs to.
Module data
Module: Temperature of the chasis in ºc
OID: .1.3.6.1.4.1.3375.2.1.3.2.3.2.1.2.1
Module type: Remote SNMP network agent, numeric data
Module: Velocity in rpm of the CPU ventilator
OID: .1.3.6.1.4.1.3375.2.1.3.1.2.1.3.1
Module type: Remote SNMP network agent, numeric data
Module: CPU Temperature
OID: .1.3.6.1.4.1.3375.2.1.3.1.2.1.2.1
Module type: Remote SNMP network agent, numeric data
Module: Used memory
OID: .1.3.6.1.2.1.1.3.0
Module type: Remote SNMP network agent, numeric data
Module: Status ventilator 1 chasis
OID: .1.3.6.1.4.1.3375.2.1.3.2.1.2.1.2.1
Module type: Remote SNMP network agent, boolean data
Module: Status ventilator 2 chasis
OID: .1.3.6.1.4.1.3375.2.1.3.2.1.2.1.2.2
Module type: Remote SNMP network agent, boolean data
Module: Status ventilator 3 chasis
OID: .1.3.6.1.4.1.3375.2.1.3.2.1.2.1.2.3
Module type: Remote SNMP network agent, boolean data
Module: Status Power source
OID: .1.3.6.1.4.1.3375.2.1.3.2.2.2.1.2.1
Module type: Remote SNMP network agent, boolean data